:+(91)-7417805283 | 8755626042 :contact@qmssurgicals.com


Defibrillators

 

Premedic DefiMonitor XD-1

The Primedic XD is a complete defibrillator package for AED /manual operation with built in carry handle. It can beusedwith hands free or paddles

Features

  • Built in strip recorder
  • 6 lead ECG via ECG cable
  • Rechargeable battery
  • Built in daily self checks Status system and battery indicator
  • British English voice prompts
  • Clear concise instructions to lead the user step by step through the rescue
  • Includes CPR and rescue breath timer and rate meter
  • Meets 2005 guidelines - and is also field up gradable to any future guidelines.
  • Real time data storage as standard
  • ECG review software as standard
  • Free onsite training

Technical Data

Defibrillation
  • Operating modes: asynchronous, external in Auto/Manual Mode
  • Synchronisation: SYNC only in Manual Mode
  • Impulse shape: biphasic, current controlled (CCD)
  • Output energy in AUTO Mode in case of:
  • Patient impedance 1. Step 2. Step 3. Step
    25 Ohm 143 J 201 J 277 J
    50 Ohm 281 J 350 J 360 J
    75 Ohm 348 J 368 J 360 J
    100 Ohm 344 J 343 J 343 J
    125 Ohm 314 J 316 J 317 J
    150 Ohm 290 J 293 J 293 J
    175 Ohm 269 J 272 J 272 J

  • Accuracy: all figures are subject to a tolerance of +/- 15%)
  • Impulse length: positive Phase 11,25 ms, negative Phase 3,75 ms
  • Discharges: 70 discharges at 20 °C with a new fully charged accumulator
  • Charging time: 12 +/-3 seconds with an accumulator with 90 percent of its nominal capacity

ECG

  • Lead: I, II, III, aVr, aVf, Avr
  • Heart rate: 30 – 300 per minute
  • Input: Class CF, for 2-pole patient cable, defibrillation proof
  • Input impedance: > 5 MOhm @ 10 Hz
  • CMRR: > 85 dB
  • Input direct voltage: ± 0,5 V
  • Bandwidth: 0,5 – 44 Hz (- 3 dB) SR = 101 Hz

Monitor

  • Monitor Type: High-resolution LCD monitor, blue mode
  • Monitor Size: 115 x 86 mm (Diagonal 144 mm, 5.7")
  • Resolution: 320 x 240 Pixel (pixel size 0.36 x 0.36 mm)
  • Displays: Heart rate, number of defibrillations, number of detected VF / VT, duration of resuscitation, date, time, accumulator capacity

Power Supply

  • AkuPak: NiCd, 12 V / 1,4 Ah
  • Integrated : 100 ... 240 Volt, 50 / 60 Hz

Data Storage

  • Memory type: CompactFlashCard (Industrial grade) 16 – 64 MB possible
  • Safety Classification: Safety Class I, Type CF, Defi-proof, medical device of Class IIb
  • Designation: The device is a medical device and meets the EU Directive 93 / 42 / EEC
  • Miscellaneous Operating conditions: 0°... 55° C, 30... 95 % rel. humidity, but without condensation 500 hPa ... 1060 hPa continuous operation
  • Storage conditions: - 20 ... 70 °C, 20 ... 95 % rel. humidity, but without condensation, 500 hPa ... 1060 hPa ...
  • Dimensions: 33 x 17 x 28 cm (width x depth x height)
  • Weight: approx. 4,5 kg (without power supply)

Used Norms

  • IEC 60601-1:1988 + A1:1991 + A2:1995
  • IEC 601-2-4:2002
  • IEC 60101-1-2:2001
  • RTCA / DO-160D: 1997 – EN1789  

Premedic DefiMonitor XD-330

The sophisticated high performance instrument with multifunctional features.It combines a compact design, tried andtrusted in practice with the highest possible degree of safety and simple handling. Range of 8 manual (XD1, XD3, XD10, XD30) or manual + AED (XD100, XD300, XD110, XD330) defibrillators with or without SpO2 and external pacer. Supplied with adult/pediatric paddles, disposable adult Save Pads, ECG cable, power cable, 1 tube gel, 1 paper roll.

Standard software: GB, FR, DE, IT, ES, PT, TR, CN. Manual: GB, IT (on request DE, ES, PT, FR, TR, CN). Other softwares and manuals available on request: CZ, FI, HU, RO, NL, NO, PL, RU, SE, SL, AE, BR, CN, IR, JP, KR, TH, USA.

Technical Data

Defibrillation
• Wave: biphasic, current controlled impulse
• Energy (automatic mode): 140-360 J
• Manual energy stages: 5J, 10J, 20J, 30J, 50J, 100J, 200J, 300J, 360J
• Charging time: < 6 sec for 200 J
• Cardio version: manual activation, QRS marker

ECG
• Derivation:
- Eindhoven I, II, III
- Goldberger, aVR, aVF, aVL
• Patient's resistance: 23-200 Ohm
• Heart rate: 30-300 per min

VF: recogniton
• VF recogniton
• Analysis time 7-12 sec
• VF threshold 200 ?V
• Asystole threshold < 200 ?V
• Artefact, Pacemaker detection

Pulse Oximeter
• Nellcor Oximax

Pacer
• Transthoracic heart pacemaker
• Modes: fix, demand, overdrive

Thermal printer
• Resolution: 200 dpi
• Advance: 25 mm/s, 50 mm/s

TFT LCD blue-mode monitor
• 115 x 86 mm (diagonal 4.7""/120 mm)
• 320 x 240 pixels

Electrodes
• Adhesive electrodes, 3 years shelf life
• Cable length 3.5 m Save pads connect

Data backup
• Removable memory 512 MB
• Data/Voice recording > 90 h
• Data/Voice recording > 75 h

Power supply
• Voltage 90-264 V, 50/60 Hz

Rechargeable Lithium-ion battery (LiFePO4)
• Capacity 2.5 Ah Voltage: 14.4 V
• Discharges 150-200 J
• Monitoring 5 h Charging time: 2.5 h

Resuscitation guidelines
• Selectable AHA/ERC

Standards
• IEC60601-1:1988+A1:1991+A2:1995 (Electrical Safety of Med. Electrical Devices)
• IEC60601-1-2:2001 (Electromagnetic compatibility)
• IEC60601-1-4:1996+A1:1999 (Programmable electrical medical systems)
• IEC60601-2-4:2002 (Defibrillators)
• EN1789:2003 (Ambulance standard)
• Protection class IP33

 

Heartsave AED

Primedic Heartsave AED is an all in one solution for First responders

  • The Heartsave AED is a complete package with built in carry handle and rescue pack which contains Electrodes, Razor, Mouth shield and Gloves under front cover
  • Always ready for immediate use
  • Standard 6 year non rechargeable battery
  • Built in daily self checks
  • Status system and battery indicator
  • British English voice prompts
  • Clear concise instructions to lead the user step by step through the rescue
  • Includes CPR and rescue breath timer and rate meter
  • Meets 2005 guidelines - and is also field up gradable to any future guidelines.
  • Real time data storage as standard ECG review software as standard
  • Free onsite training

Technical Data

Defibrillation:
• Wave: biphasic, current controlled
• Energy 140-360 j
• Charging time: < 12 sec
• Operating modes: asynchronous

ECG
• Lead: II
• Patient's impedance range: 20-200 Ohm
• Heart rate: 30-300 per min

VF:VT Detection
• VF/VT Detection
• Analysis time 6-12 sec
• VF threshold 0.2 mV
• Asystole threshold < 0.2mV
• Artefact-Pacemaker detection

Electrodes
• Non polarized electrodes, 2 years storage
• Cable length 1.5 m

Data backup
• Internal memory 8 MB backup
• Removable memory 32-128 MB
• Voice recording

Power supply
• Lithium battery or Rechargeable (Power pack 90-260 V, 50/60 Hz)
• Battery: Lithium | Rechargeable
• Type: LiMnO2 | NiCd
• Battery storage: 5 Years
• Discharges: 200 | 56
• Monitoring: 11 h | 5 h
• Voltage: 16 V | 10.6V

Heartsave AED-M

The convincing feature of the new PRIMEDIC HeartSave is its easy, safe and speedy operation. With the new biphasic "Current Controlled Defibrillation" pulse, we are setting new standards in defibrillation technology.
The device performs an automatic ECG analysis within 12 seconds and decides whether a defibrillation is necessary.
Then a touch of a button is enough to trigger the life-saving electric pulse that eliminates the ventricular fibrillation.
Thus valuable seconds and minutes are used to save life.
Automatic external defibrillator incl. monitor for indication of operation duration, ECG, heart rate, identified VF/VT as well as triggered defibrillations.

Features

  • One-button operation
  • Intuitive and easily handling
  • Status indicator
  • Can be operated from mains, battery and accumulators
  • No energy selection required
  • Charging time < 10 sec. 3-shock cycle < 60 sec.
  • SaveCard, at least 60 minutes, for internal ECG and voice recording.
  • Regular self-test
  • Dim. approx. 26x26x8,5 cm, weight approx. 2 kg
  • Made in Germany

Technical Data

Defibrillation

  • Wave: biphasic, current controlled pulse
  • Energy 140-360 j
  • Charging time: < 12 sec
  • Operating modes: asynchronous

ECG

  • Lead: II
  • Patient's impedance range: 20-200 Ohm
  • Heart rate: 30-300 per min VF:VT
  • Detection: VF/VT Detection
  • Analysis time 6-12 sec VF threshold 0,2 mV
  • Asystole threshold < 0,2mV
  • Artefact-Pacemaker detection

LCD Monitor

  • 95 x 72 mm (diagonal 4.7"/120 mm)
  • 320 x 240 (pixel size 0,36 x 0,36 mm)
  • Storage battery status display
  • Speed 25 mm/s
  • Heart rate, number of defibrillation, number of VF/VT, total resuscitation time

Electrodes

  • Non polarized electrodes, 2 years storage
  • Cable length 1,5 m


Data backup

  • Internal memory 8 MB backup
  • Removable memory 32-128 MB
  • Voice recording


Power supply

  • Rechargeable (Power pack 90-260 V, 50/60 Hz)
  • Battery: Rechargeable
  • Type: NiCd
  • Discharges: 56
  • Monitoring: 5 h
  • Voltage: 10,6 V

 

Heartsave 6

The convincing feature of the new PRIMEDIC™ HeartSave is its easy, safe and speedy operation. With the new biphasic "Current Controlled Defibrillation" pulse, we are setting new standards in defibrillation technology.The device performs an automatic ECG analysis within 12 seconds and decides whether a defibrillation is necessary.Then a touch of a button is enough to trigger the life-saving electric pulse that eliminates the ventricular fibrillation. Thus valuable seconds and minutes are used to save life.



Features
  • One-button operation
  • Intuitive and easily handling
  • Status indicator
  • Lithium-battery
  • No energy selection required
  • Current controlled defibrillation
  • SaveCard, 100 hours for internal ECG andvoice recording
  • Regular self-test
  • Dimensions: approx. 26 x 26 x 8.5 cm
  • Weight: approx. 2 kg
  • Made in Germany

Technical Data

Defibrillation
• Wave: biphasic, current controlled
pulse
• Energy 140-360 j
• Charging time: < 12 sec
• Operating modes: asynchronous

ECG
• Lead: I, II, III, aVr, aVf, aVI
• Patient's impedance range: 20-200 Ohm
• Heart rate: 30-300 per min

VF:VT Detection
• VF/VT Detection
• Manual override
• Analysis time 6-12 sec
• VF threshold 0,2 mV
• Asystole threshold <0,2mV
• Artefact-Pacemaker detection

LCD Monitor
• 95 x 72 mm (diagonal 4.7"/120 mm)
• 320 x 240 (pixel size 0,36 x 0,36 mm)
• Storage battery status display
• Speed 25 mm/s
• Heart rate, number of defibrillation, number of VF/VT,
• Total resuscitation time

Electrodes
• Non polarized electrodes, 2 years storage
• Cable length: 1.5 m

Data backup
• Internal memory 8 MB backup
• Removable memory 32-128 MB
• Voice recording

Power supply
• Lithium battery or Rechargeable (Power pack 90-260 V, 50/60 Hz)
• Battery: Lithium | Rechargeable
• Type: LiMnO2 | NiCd
• Battery storage: 5 Years
• Discharges: 110 | 56
• Monitoring: 11 h | 5 h
• Voltage: 16 V | 10,6 V